Specification
| Model | PPKP-24 | ||
| Heating Capacity Range | kW | 9-26 | |
| Heating (A7/6℃,W30/35℃) |
Heating Capacity | kW | 24.2 |
| Power Input | kW | 5.82 | |
| COP | W/W | 4.17 | |
| Heating (A-12℃,W36/41℃) |
Heating Capacity | kW | 19.3 |
| Power Input | kW | 7.55 | |
| COP | W/W | 2.55 | |
| Heating (A7/6℃,W40/45℃) |
Heating Capacity | kW | 21.8 |
| Power Input | kW | 6.36 | |
| COP | W/W | 3.43 | |
| Heating (A7/6℃,W47/55℃) |
Heating Capacity | kW | 19.6 |
| Power Input | kW | 6.73 | |
| COP | W/W | 2.92 | |
| Cooling (A35/24℃,W23/18℃) |
Cooling Capacity | kW | 26.1 |
| Power Input | kW | 6.7 | |
| EER | W/W | 3.89 | |
| Cooling A35/24℃,W12/7℃) | Cooling Capacity | kW | 20.5 |
| Power Input | kW | 6.5 | |
| EER | W/W | 3.15 | |
| Maximum input power | kW | 9.2 | |
| High Pressure Value Cut-off Pressure | MPa | 4.2Mpa | |
| Low Pressure Valve Cut-off Pressure | MPa | 0.05Mpa | |
| Brand/Type of Compressor | / | panasonic | |
| Brand of EEV | EEV | SANHUA | |
| Brand Of 4-way Valve | SANHUA | ||
| Brand Of Water Pump | / | ||
| Waterproof Grade | I | IPX4 | |
| Noise Pressure | dB(A) | 57 | |
| Max Water Outlet Ternperature | °C | 55 | |
| Diameter Of Water Connection | / | DN40(1.5") | |
| Drainage Valve | mm | / | |
| Lowest Operationa I point, outdoor air/flow line (heating mode ) |
-25 | ||
| Highest Operationa I point, outdoor air/flow line (heating mode ) |
43 | ||
| Package Dimensions ( L/W/H ) | mm | 1250*520*1697 | |
| Gross Weight | KG | 203 | |